SR9009 Identity and Mechanism

SR9009 is frequently discussed alongside other REV-ERB ligands, including synthetic agonists and natural heme-related molecules. Its selectivity for REV-ERB over related nuclear receptors has been measured in binding and reporter assays, though off-target activity at higher concentrations is possible. The compound is prohibited in sport by the World Anti-Doping Agency, and it is not approved for any medical use in major jurisdictions. Products sold online may be labeled as research chemicals, and their identity and purity are not guaranteed by regulatory review.

SR9009 is a synthetic small molecule that acts on the nuclear receptors REV-ERBα and REV-ERBβ. These receptors are part of the circadian clock machinery and normally repress transcription of certain target genes. In laboratory research, SR9009 is used as a chemical tool to study how REV-ERB activity influences metabolism, inflammation, and daily biological rhythms. The compound is not an approved medicine, and its effects in humans remain largely uncharacterized. It is often described as an investigational agent rather than a therapeutic product.

REV-ERB proteins typically suppress gene expression by recruiting corepressor complexes to DNA response elements. SR9009 binds these receptors and strengthens that repressive action in cell-based assays. Studies in rodents have reported changes in lipid handling, mitochondrial function, and exercise capacity after treatment. Such findings are often cited as evidence for metabolic effects, but species differences and limited pharmacokinetic data make direct translation to humans uncertain. Researchers continue to examine which effects are robust and which depend on specific experimental conditions.

Analytical and Handling Considerations

SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.

For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.

Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.

Sr9009 at a glance

PropertyValueNotes
Common nameSR9009Also marketed informally as Stenabolic
Chemical classSynthetic REV-ERB agonistBinds REV-ERBα and REV-ERBβ
Molecular formulaC24H30ClN3O4SApproximate molecular weight 492 g/mol
CAS Registry Number1379686-30-2Identifier for the parent compound
Regulatory statusNot approved for human useProhibited in sport by WADA

Analytical Detection and Storage

Quality control for research materials includes identity confirmation by nuclear magnetic resonance and purity assessment by high-performance liquid chromatography. Mass spectrometry provides molecular weight confirmation and can detect related impurities. Purchasers should request a certificate of analysis that lists lot-specific data. Online products advertised for human use often lack such documentation. Distinguishing legitimate research material from mislabeled or contaminated samples is a recurring challenge in independent testing, and independent laboratories may use orthogonal methods to verify identity.

Detection of SR9009 in biological samples usually relies on liquid chromatography coupled to tandem mass spectrometry. This approach separates the compound from matrix components and identifies it by mass transitions. Because SR9009 can undergo metabolism, laboratories often look for both parent drug and specific metabolites. Sample preparation may involve protein precipitation or solid-phase extraction. Method validation examines sensitivity, carryover, and interference from related substances, and reference standards are required for accurate calibration.

Related pages on this site

Detection, Regulation, and Misconceptions

Several misconceptions surround SR9009. It is often described as a SARM, a steroid, or an exercise pill, but its known target is the REV-ERB receptor family. Rodent studies have examined exercise capacity and metabolic markers, yet human outcomes remain unproven. Oral bioavailability appears low in animals, and human pharmacokinetics are not well characterized. Online products may contain impurities or different compounds, so identity and purity testing are important for research use.

Analytical chemists detect SR9009 with liquid chromatography-tandem mass spectrometry, commonly abbreviated LC-MS/MS. Sample preparation may involve protein precipitation, liquid-liquid extraction, or solid-phase extraction before analysis. Laboratories can target the parent compound or its metabolites, depending on the matrix and the purpose of testing. Anti-doping methods require sensitive and specific assays because concentrations in biological samples can be low. Reference standards and validated methods are essential for reliable identification and quantification.

Analytical Detection and Regulatory Status

Regulatory treatment of SR9009 reflects its investigational status. The compound has no approved human therapeutic indication, and sports authorities prohibit its use. It appears on anti-doping lists as a non-approved substance or metabolic modulator, depending on the list version. Products sold online as research chemicals are not quality-controlled medicines, so their identity and purity can differ from the label. Such products may also contain unlisted compounds, which complicates both testing and safety assessment.

Scientific discussion of SR9009 often separates animal evidence from human anecdote. Rodent studies provide controlled data on endurance, metabolism, and gene expression, but they use specific strains, doses, and treatment durations. Human reports are mostly uncontrolled and cannot establish cause and effect. Open questions include oral bioavailability, tissue distribution, metabolic stability, and long-term effects. Review articles generally call for more rigorous pharmacokinetic and safety research before any clinical use could be considered.

Analytical methods for SR9009 typically rely on liquid chromatography coupled with tandem mass spectrometry. The technique can separate the parent compound from related substances and detect low concentrations in biological matrices. Urine and blood are common samples in anti-doping testing, while in vitro studies may use cell culture media. Rapid metabolism and low expected concentrations make method validation important for reliable identification. Exact metabolite patterns can vary by species and are not fully mapped.

Handling Storage and Quality Control

Laboratory samples of SR9009 are typically supplied as a white to off-white powder. The compound dissolves readily in organic solvents such as dimethyl sulfoxide and ethanol, while its solubility in water is low. Because of this solubility profile, researchers often prepare concentrated stock solutions in an organic solvent before diluting them into aqueous assay buffers. Light exposure, moisture, and repeated freeze-thaw cycles can degrade many small molecules, so handling procedures usually aim to minimize these factors. Purity is commonly checked before use.

Storage conditions for research-grade SR9009 generally involve a freezer at approximately minus twenty degrees Celsius, sometimes lower for long-term preservation. Containers should remain tightly closed and protected from light. Desiccants may be used to limit moisture uptake. Solutions are often stored in aliquots to avoid repeated warming and cooling. Stability data for the compound under various conditions are limited, so laboratories typically follow supplier recommendations and verify performance through periodic analytical checks rather than assuming indefinite stability.

Background from the literature

Albersheim P, Killias U (1962). "Studies relating to the purification and properties of pectin transeliminase". Arch. Biochem. Biophys. 97 (1): 107–15. doi:10.1016/0003-9861(62)90050-4. PMID 13860094. Edstrom RD, Phaff HJ (1964). "Purification and Certain Properties of Pectin trans-Eliminase from Aspergillus fonsecaeus". J. Biol. Chem. 239 (8): 2403–8. doi:10.1016/S0021-9258(18)93866-4. PMID 14235514. Edstrom RD, Phaff HJ (1964). "Eliminative Cleavage of Pectin and of Oligogalacturonide Methyl Esters by Pectin trans-Eliminase". J. Biol. Chem. 239 (8): 2409–15. doi:10.1016/S0021-9258(18)93867-6. PMID 14235515. Nagel CW, Vaughn RH (1961). "The degradation of oligogalacturonides by the polygalacturonase of Bacillus polymyxa". Arch. Biochem. Biophys. 94 (2): 328–32. doi:10.1016/0003-9861(61)90047-9. PMID 13727438. Nasuno S, Starr MP (1967). "Polygalacturonic acid trans-eliminase of Xanthomonas campestris". Biochem. J. 104 (1): 178–85. doi:10.1042/bj1040178. PMC 1270559. PMID 6035509. Pickersgill R, Jenkins J (1997). "Two crystal structures of pectin lyase A from Aspergillus reveal a pH-driven conformational change and striking divergence in the substrate-binding clefts of pectin and pectate lyases". Structure. 5 (5): 677–89. doi:10.1016/S0969-2126(97)00222-0. PMID 9195887.

It is used to join DNA pieces containing genes, regulatory sequences, or mutations; the technique enables creation of specific and long DNA constructs. It can also introduce deletions, insertions or point mutations into a DNA sequence. PAN-AC: uses isothermal conditions for amplification, and may be used in living cells. PAN-PCR: A computational method for designing bacterium typing assays based on whole genome sequence data. Quantitative PCR (qPCR): used to measure the quantity of a target sequence (commonly in real-time). It quantitatively measures starting amounts of DNA, cDNA, or RNA. Quantitative PCR is commonly used to determine whether a DNA sequence is present in a sample and the number of its copies in the sample. Quantitative PCR has a very high degree of precision. Quantitative PCR methods use fluorescent dyes, such as Sybr Green, EvaGreen or fluorophore-containing DNA probes, such as TaqMan, to measure the amount of amplified product in real time. It is also sometimes abbreviated to RT-PCR (real-time PCR) but this abbreviation should be used only for reverse transcription PCR. qPCR is the appropriate contractions for quantitative PCR (real-time PCR). Reverse complement PCR (RC-PCR): Allows the addition of functional domains or sequences of choice to be appended independently to either end of the generated amplicon in a single closed tube reaction. This method generates target specific primers within the reaction by the interaction of universal primers (which contain the desired sequences or domains to be appended) and RC probes.

The word "soviet" is derived from the Russian word sovet (Russian: совет), meaning 'council', 'assembly', 'advice', ultimately deriving from the proto-Slavic verbal stem of *vět-iti ('to inform'), related to Slavic věst ('news') and English wise. The word sovietnik means 'councillor'. Some organizations in Russian history were called council (Russian: совет). In the Russian Empire, the State Council, which functioned from 1810 to 1917, was referred to as a Council of Ministers. The soviets as workers' councils first appeared during the 1905 Russian Revolution. Although they were quickly suppressed by the Imperial army, after the February Revolution of 1917, workers' and soldiers' soviets emerged throughout the country and shared power with the Russian Provisional Government. The Bolsheviks, led by Vladimir Lenin, demanded that all power be transferred to the soviets, and gained support from the workers and soldiers. After the October Revolution, in which they seized power from the Provisional Government in the name of the soviets, Lenin proclaimed the formation of the Russian Socialist Federal Soviet Republic (RSFSR). During the Georgian Affair of 1922, Lenin called for the Russian SFSR and other national soviet republics to form a greater union which he initially named as the Union of Soviet Republics of Europe and Asia (Russian: Союз Советских Республик Европы и Азии, romanized: Soyuz Sovyetskikh Respublik Evropy i Azii).

Total publications: 518 Publications in international journals: 315 Cumulative impact factor: 902 Citations (Google Scholar): over 12,600 Independent citations (MTMT): 6,864 Hirsch index (Google Scholar): 55

Sources: en.wikipedia.org

Further detail

== Adverse effects == Some adverse events reported in preliminary clinical trials are somnolence, agitation, nausea, diarrhea, and dyspepsia. The adverse effect profile of ulotaront differs from that of other antipsychotics because its mechanism of action does not involve antagonism of dopamine receptors in the brain, which is responsible for the drug-induced movement disorders (like akathisia) that may occur with those agents.

Low-fat diets may not be an effective long-term intervention for obesity: as Bacon and Aphramor wrote, "The majority of individuals regain virtually all of the weight that was lost during treatment." The Women's Health Initiative ("the largest and longest randomized, controlled dietary intervention clinical trial") found that long-term dietary intervention increased the waist circumference of both the intervention group and the control group, though the increase was smaller for the intervention group. The conclusion was that mean weight decreased significantly in the intervention group from baseline to year 1 by 2.2 kg (p<.001) and was 2.2 kg less than the control group change from baseline at year 1. This difference from baseline between control and intervention groups diminished over time, but a significant difference in weight was maintained through year 9, the end of the study.

== Applications == Chromatography is used in many fields including the pharmaceutical industry, the food and beverage industry, the chemical industry, forensic science, environment analysis, and hospitals.

Pharmaceutical formulation, in pharmaceutics, is the process in which the active drug or Active Pharmaceutical Ingredient (API) is combined with different chemical substances to produce a final medicinal product. The word formulation is often used in a way that includes dosage form.

Metallopeptides (also called metal-peptides or metal peptide complexes) are peptides that contain one or more metal ions in their structure. This specific type of peptide are, just like metalloproteins, metallofoldamers. And very similar to metalloproteins, metallopeptide's functionality is attributed through the contained metal ion cofactor. These short structured peptides are often employed to develop mimics of metalloproteins and systems similar to artificial metalloenzymes. A multitude of naturally occurring peptides display biological and chemical activities when bound to various metal ions. Where different metal ion cofactor can lead to different reactivity and even different folding and physical characteristics (e.g. solubility or stability) of the structure. Synthetic equivalents of such peptides are engineered to bind metal ions and display a variety of physical, chemical, and biological reactivity and characteristics.

Sources: en.wikipedia.org

Frequently asked questions

What is SR9009?

SR9009 is a synthetic research compound that binds and modulates the nuclear receptors REV-ERBα and REV-ERBβ. It is used in laboratory studies of circadian biology and metabolism, not as an approved medicine. It is also known by the informal name Stenabolic.

Is SR9009 approved for human use?

No. SR9009 has not been approved as a therapeutic drug in the United States, European Union, or other major markets. Human safety and efficacy data are very limited. Its presence in consumer products does not imply regulatory approval.

Why is SR9009 banned in sport?

The World Anti-Doping Agency lists SR9009 as a prohibited substance because it can alter gene expression and metabolic pathways relevant to performance. The ban applies at all times, not only during competition. Detection relies on laboratory methods such as mass spectrometry.

How is SR9009 detected in laboratory samples?

Liquid chromatography with mass spectrometry is a common approach. Ultraviolet detection and nuclear magnetic resonance can support identification when suitable standards are available.